Operating instructions
Weigh the sample, pivot the radiator above it, the measurement starts automatically and ends when the weight is constant. All of the parameters can be changed in the menu using three buttons. The menu is shown in the LC display.
The radiation temperature can also be set anywhere between 105 °C and 360 °C.
The moisture content can be determined using a timer or the automatic cut-out. Three criteria are individually set for the automatic cut-out depending on the product properties: query start, weight reduction and query interval.
The measurement result remains on the display until the device is next used.
More opportunities as a result of temperatures of up to 600 °C!
The reusable stainless steel sample dishes mean an ongoing cost saving.
Moisture analyser ULTRA X 3011QD
The ULTRA X 3011HQ can optionally be delivered with or without a built-in printer. The printout of all data is carried out in line with GLP. Intermediate values can be printed out at selectable intervals as needed. All of the data are also output via the serial RS 232 interface and USB. The printer can be switched off.
Technical data
Balance
Weighing range: 200 g
Resolution: 0.001 g
Sample volume: max. 95 cm³
Drying bowl: 110 mm diameter
For moisture measuring
Sample weight: any, recommended minimum 4 g
Power of heater: 375 watts
Automatic: automatic drying until weight constant selectable in 3 different modes: start measuring, measuring in intervals, weight loss / measured during intervals
Timer: 1-180 minutes
Temperature: selectable from 120 °C up to 600 °C
Measured values: % moisture, % dry mass, % moisture ad actual sample weight, g solids per kg
Measuring accuracy: 0.01%
Device identification: 4-digit ID for identifying the device
Menu lock: lock the menu to prevent accidental changes to drying parameters, cal function is further available
Communication
Data output: interface V24 RS 232
Data signals: all weight and measuring data in GLP-format with start time and variable interval print out selectable date, time, total measuring time, type of sample
With Software ULTRA X DataChannel to transfer on PC as .xls file for Microsoft Excel, .html file, .xml file and .txt file.
For using
Power supply: 230 V 20% / + 15%
Supply frequency: 48-63 Hz
Power consump.: 400 VA
Dimensions: approx. l 385 x w 275 x h 240 mm over all
Weight: approx. 8.5 kg
Accessories
Stainless-steel drying tray | part no. 1000282
Sample tongs (2 sets supplied with the device)
Tray tongs | part no. 1000230
For lifting the tray (supplied with the device)
Power cable | part no. 1000190
Power supply (supplied with the device)
Calibration weight F1 200 g | part no. 1000403
For calibrating the balance
Aluminium foils 130 mm diameter, 0.01 mm | part no. 1000016
For lining the drying tray
Aluminium foils 130 mm diameter, 0.03 mm | part no. 1000017
For lining the drying tray
Foil press | part no. 1000062
For shaping the aluminium foil
Consumables
Paper for printer 58 mm | part no. 1000234
For integrated printer
Thermal paper
Durable 10 years, according to manufacturer
Quartz heater| part no. 1000139
Spare part
Applications
ULTRA X – instruments you will find in almost all fields!
Raw material exploitation – production – processing – storage – trade – research – recycling – monitoring
ULTRA X 3011HQ
- All temperature-insensitive substances up to 600 °C
- Building materials
- Cement, concrete, gravel etc.
- Chemical industry
Powder, granules, paste etc.
- Treatment plant
Sludge